Seitenansicht 67
SanDisk Industrial Grade CompactFlash 5000 Product Manual
© 2007 SanDisk® Corporation 61 July 2007
Table 59 defines the valid extended error codes for the CompactFlash Memory
Card Series product. The extended error code is returned to the host in the
Error Register. This command must be the subsequent command issued to the
card following the command that returned an error.
Table 59:
Extended Error Codes
Extended Error Code Description
00h No error detected
01h Self test OK (no error)
09h Miscellaneous error
20h Invalid command
21h Invalid address (requested head or sector invalid)
2Fh Address overflow (address too large)
35h, 36h Supply or generated voltage out of tolerance
11h Uncorrectable ECC error
18h Corrected ECC error
05h, 30-34h, 37h, 3Eh Self test or diagnostic failed
10h, 14h ID not found
3Ah Spare sectors exhausted
1Fh Data transfer error/aborted command
0Ch, 38h, 3Bh, 3Ch, 3Fh Corrupted media format
03h Write/erase failed
5.1.17
Seek–7XH
This command is effectively a NOP command to the card, although it does
perform a range check of cylinder and head or LBA address and returns an
error if the address is out of range.